B2OC: Lb2LcPi Run 3 analysis, re-run hlt2 without PID cuts to extract the efficiency of the PID cuts applied at hlt2 (UPDATE)
- at present there is no agreement between the PID in data and simulation, see https://indico.cern.ch/event/1455019/contributions/6236126/attachments/2970499/5227503/2024MC-b2oc-em-feedback.pdf pag 8 and 9
- but MC is produced with the same PID cuts used for the hlt2 processing of the 2024 data
- so we have to extract the PID efficiency on MC re-running the hlt2 without PID cuts and correct MC for it, hence this AProd
- the PID efficiency on data is obtained from PIDCalib2
- similar to !2183 (merged)
- please delete the previous version: !2186 (merged) which had the wrong decay descriptor number (cc @abertoli)
- (supersedes !2186 (merged))
Edited by Maciej Artur Giza