BugFix of DECfiles: The incorrect arrows for the DecayDescriptor in the tool tightCut.Decay result…
The incorrect arrows for the DecayDescriptor in the tool tightCut.Decay result in an unphysical asymmetry of cos(theta_L). This problem is resolved by changing the arrows from -> to => This effects the following DECfiles: 12115178 and 12113445.
Release.note text: ! 2019-01-23 - David Gerick modify two decfiles for B+->K*+ mu mu decays, changing arrows in tightCut.Decay (-> to =>)
- 12113445 : Bu_Kstmumu,Kpi0=PHSP,flatq2,DecProdCut,TightCut.dec
- 12115178 : Bu_Kstmumu,KSpi=PHSP,flatq2,DecProdCut,TightCut.dec