Add one new line called Hlt1TauToPhiMuLine
Dependencies
General Description
MR related to the proposal on the implementation of a new Hlt1 trigger line designed to select \phi(1020)(\to K^+K^-) + \mu decays.
This exclusive line selects \tau\to\phi(KK)\mu events by combining a neutral vertex (a dihadron vertex) with a third track (a muon).
- Proponents: Domenico Riccardi, Michael J. Morello, Giovanni Punzi, Matteo Rama.
The general idea of the algorithm is (for the complete selections list, see the table below):
- Exploit \phi(1020) mass to select \phi\to K^{+}K^{-} candidates + other kinematic selections.
- Exploit
is_muonrequirement to select the third track + other kinematic selections. - Final tau candidate found requiring the \tau mass + DOCA(\phi,\mu) to select the closest \mu to \phi + PT and c\tau of the \phi\mu system.
See my last presentation at the WP3 meeting for further details.
- Name of the new line implemented:
Hlt1TauToPhiMu - Exclusive
Hlt1TauToPhiMurate = 3.5\pm1.0\,\rm{kHz} (first version, v1, now replaced by v1.1).
Update
- A new version of the
Hlt1TauToPhiMu(v1.1) line has been implemented, operating at a lower rate compared to the first version. - The rate was computed using MinBias samples located at:
/eos/lhcb/wg/rta/WP3/bandwidth_division/Beam6800GeV-expected-2024-MagDown-Nu7.6/30000000/. The table below summarizes the test results for the newHlt1TauToPhiMuline, including performance comparisons withHlt1TwoTrackMVAandHlt1TrackMuonMVA(the other two important line to select our signal):
| Line name | Total events | Inclusive rate [kHz] |
|---|---|---|
Hlt1TwoTrackMVA |
11266/564308 | 598.93 +/- 5.59 |
Hlt1TauToPhiMu |
56/564308 | 2.98 +/- 0.40 |
Hlt1TrackMuonMVA |
1016/564308 | 54.01 +/- 1.69 |
Total Hlt1 rate with Hlt1TauToPhiMu |
23503/564308 | 1249.48 +/- 7.98 |
Total Hlt1 rate w/o Hlt1TauToPhiMu |
23472/564308 | 1247.83 +/- 7.97 |
- Based on these results, the exclusive rate of the
Hlt1TauToPhiMuline in its new configuration is (1.65 ± 0.30) kHz (new version v1.1).
Table of the implemented selection in version v1.1:
- The new selections implemented in v1.1 are \chi^2_{FD}(\phi) > 10 and a tighter cut on \chi^2_{IP}(\mu) > 9 (previously > 4).
Description of the v2 version (latest)
- New version of the
Hlt1TauToPhiMuline implemented to avoid introducing a new container. The new version uses the existingdihadroncontainer without changes. - Fine-tuning of the selections implemented in the CUDA line code. The updated configuration is shown in the table below.
- New exclusive rate = 1.12 +/- 0.24 kHz (reduced by a factor of 3 compared to the first version of the line).
- Rate computed using all available MinBias samples at
/eos/lhcb/wg/rta/WP3/bandwidth_division/Beam6800GeV-expected-2024-MagDown-Nu7.6/30000000/with the Allen sequencehlt1_pp_forward_then_matching_1000KHz.
Reviewer assignment
Edited by Tommaso Fulghesu