Add HLT2 Single High PT NoMuID Muon line

Ross John Hunter requested to merge rjhunter-nomuid-lines into qee_upgrade

FYI @wbarter @lcalefic @ncooke @jideng @yqiu @lsestini @cvazquez @hyin @dzuliani

First try at adding a NoMuID high-pT single muon line. Essentially exactly the same as the Hlt2SingleHighPtMuonLine but instead of using make_ismuon_long_muons, which require ISMUON, I just use make_long_muons. I applied a 10% prescale as a first guess and the rate seems reasonable (although time consuming to check with any precision). With 10k events:

Line:	 Hlt2SingleHighPtMuonIsoLineDecision     	 Incl: 0.2  +/- 0.14 kHz, Excl: 0.1  +/- 0.09 kHz
Line:	 Hlt2SingleHighPtMuonLineDecision        	 Incl: 0.1  +/- 0.09 kHz, Excl: 0.0  +/- 0.0  kHz
Line:	 Hlt2SingleHighPtMuonNoMuIDLineDecision  	 Incl: 0.1  +/- 0.09 kHz, Excl: 0.1  +/- 0.09 kHz

Efficiencies on W+jet with 1k events:

Line:	 Hlt2SingleHighPtMuonIsoLineDecision           	 Efficiency:	 0.846 +/- 0.018
Line:	 Hlt2SingleHighPtMuonLineDecision              	 Efficiency:	 0.949 +/- 0.011
Line:	 Hlt2SingleHighPtMuonNoMuIDLineDecision        	 Efficiency:	 0.098 +/- 0.015
Line:	 Hlt2SingleHighPtMuonPrescaleLineDecision      	 Efficiency:	 0.056 +/- 0.012