BNV and LFV lines
- Prototype for some Baryon Number Violation lines:
- B0 -> p mu
- Lz -> pi/K mu
- Lb -> pi/K mu
- B0 -> Lc mu
- Lb -> Ds mu
- Prototype for some similar Lepton Flavour Violation lines:
- B0 -> pi/K mu
- Lz -> p mu
- Lb -> p mu
-
For all channels two lines are defined, one with the right charge, one with the wrong charge (SS)
-
Rates are measured on testfiledb_key:
upgrade_minbias_hlt1_filtered
:
1.1 Hlt2RD_BToPpMu_Line 0.07 +/- 0.07 kHz
1.2 Hlt2RD_BToPpMu_SS_Line 0.0 +/- 0.0 kHz
2.1 Hlt2RD_LambdaToPipMu_Line 0.0 +/- 0.0 kHz
2.2 Hlt2RD_LambdaToPipMu_SS_Line 0.0 +/- 0.0 kHz
3.1 Hlt2RD_LambdaToKpMu_Line 0.0 +/- 0.0 kHz
3.2 Hlt2RD_LambdaToKpMu_SS_Line 0.7 +/- 0.0 kHz
4.1 Hlt2RD_LbToPipMu_Line 0.0 +/- 0.0 kHz
4.2 Hlt2RD_LbToPipMu_SS_Line 0.0 +/- 0.0 kHz
5.1 Hlt2RD_LbToKpMu_Line 0.07 +/- 0.07 kHz
5.2 Hlt2RD_LbToKpMu_SS_Line 0.0 +/- 0.0 kHz
6.1 Hlt2RD_BToLcMu_Line 0.07 +/- 0.07 kHz
6.2 Hlt2RD_BToLcMu_SS_Line 0.0 +/- 0.0 kHz
7.1 Hlt2RD_LbToDsMu_Line 0.0 +/- 0.0 kHz
7.2 Hlt2RD_LbToDsMu_SS_Line 0.0 +/- 0.0 kHz
8.1 Hlt2RD_BToPipMu_Line 0.0 +/- 0.0 kHz
8.2 Hlt2RD_BToPipMu_SS_Line 0.0 +/- 0.0 kHz
9.1 Hlt2RD_BToKpMu_Line 0.0 +/- 0.0 kHz
9.2 Hlt2RD_BToKpMu_SS_Line 0.0 +/- 0.0 kHz
10.1 Hlt2RD_LambdaToPMu_Line 0.07 +/- 0.07 kHz
10.2 Hlt2RD_LambdaToPMu_SS_Line 0.07 +/- 0.07 kHz
11.1 Hlt2RD_LbToPpMu_Line 0.07 +/- 0.07 kHz
11.2 Hlt2RD_LbToPpMu_SS_Line 0.07 +/- 0.07 kHz
- Following @msaur suggestion, prescale factors are introduced to control rates