Hlt2 line for Bs2taumu LFV decay
HLT2 line for the following LFV decay:
B_(s)0 -> tau (-> 3pi nu_tau) mu
B_(s)0 -> tau (-> 3pi nu_tau) e
Rate:
The rates is evaluated for the upgrade_minbias_hlt1_filtered dataset:
Line: Hlt2RD_BsToTauMu_TauTo3Pi_LineDecision Incl: 0.26696923179603554 +/- 0.13 kHz, Excl: 0.26696923179603554 +/- 0.13 kHz
Hlt2 Total: Rate: 0 +/- 0.1 kHz
Update 07-03-2022:
Line: Hlt2RD_BsToTauE_TauTo3Pi_OS_LineDecision Incl: 0.07692307692307693 +/- 0.07 kHz, Excl: 0.07692307692307693 +/- 0.07 kHz
Line: Hlt2RD_BsToTauMu_TauTo3Pi_OS_LineDecision Incl: 0.07692307692307693 +/- 0.07 kHz, Excl: 0.07692307692307693 +/- 0.07 kHz
Hlt2 Total: Rate: 0 +/- 0.1 kHz
Signal rates:
MC Signal | Event Type | Hlt2 Line | Total # | Passed # | Efficiency[%] |
---|---|---|---|---|---|
Bs -> mu tau |
13110004 | Hlt2RD_BsToTauMu_TauTo3Pi_Line | 20124 | 737 | 3.662294 +/- 0.132409 |
Update 03-03-2022:
MC Signal | Event Type | Hlt2 Line | Total # | Passed # | Efficiency[%] |
---|---|---|---|---|---|
Bs -> mu tau |
13110004 | Hlt2RD_BsToTauMu_TauTo3Pi_Line | 20000 | 698 | 3.490000 +/- 0.129773 |
Edited by Olaf Massen