Skip to content

Add Electron PID HLT2 lines for Calib Stream

Seophine Stanislaus requested to merge sstanisl-pid-electrons2 into master

Two sets of lines. One set is a copy of the Run 2 selection and includes PIDe cut on tag electron. Other set (labelled with noPIDe in line name) does not include PIDe on tag electron, instead tighter B, e (tag and probe) and K cuts.

Rates run over 60K min bias events

Efficiencies run over Upgrade MC that is not HLT1 filtered

Total integrated rate of all lines: 572 Hz

Lines, their rates, and their efficiencies (HLT1+HLT2)

Line Rate (Hz) Efficiency (%)
Hlt2PID_BToKJpsi_JpsiToEmbremEpbrem_Tagged_Line 219 6.0
Hlt2PID_BToKJpsi_JpsiToEmbremEpbrem_Tagged_noPIDe_Line 101 6.6
Hlt2PID_BToKJpsi_JpsiToEmbremEp_Tagged_Line 202 2.9
Hlt2PID_BToKJpsi_JpsiToEmbremEp_Tagged_noPIDe_Line 101 3.7
Hlt2PID_BToKJpsi_JpsiToEmEpbrem_Tagged_Line 219 5.1
Hlt2PID_BToKJpsi_JpsiToEmEpbrem_Tagged_noPIDe_Line 84 5.5
Hlt2PID_BToKJpsi_JpsiToEmEp_Tagged_Line 202 2.5
Hlt2PID_BToKJpsi_JpsiToEmEp_Tagged_noPIDe_Line 84 3.2
Hlt2PID_BToKJpsi_JpsiToEmbremEpbrem_Tagged_Line 219 6.6
Hlt2PID_BToKJpsi_JpsiToEmbremEpbrem_Tagged_noPIDe_Line 101 6.6
Hlt2PID_BToKJpsi_JpsiToEpbremEmbrem_Tagged_Line 135 6.2
Hlt2PID_BToKJpsi_JpsiToEpbremEmbrem_Tagged_noPIDe_Line 118 6.6
Hlt2PID_BToKJpsi_JpsiToEpEmbrem_Tagged_Line 118 5.0
Hlt2PID_BToKJpsi_JpsiToEpEmbrem_Tagged_noPIDe_Line 118 5.1
Hlt2PID_BToKJpsi_JpsiToEpEm_Tagged_Line 118 3.7
Hlt2PID_BToKJpsi_JpsiToEpEm_Tagged_noPIDe_Line 84 4.1

@smalde @sstanisl

Edited by Seophine Stanislaus

Merge request reports