QEE: Migrate the single muon HLT2 lines to ThOr
Shifters please ignore
Now that ThOr has a SUMCONE
functor, the HLT2 single, high-pt muon lines can be migrated to ThOr. At the moment, this functor does not remove the signal track from the cone, so the signal is manually removed by removing the track's pT from the sum. When the signal removal is added to SUMCONE
, this can be removed. I will open an issue to make sure this is tracked.
Very small change in efficiency firing on 1k Z \to \mu\mu
events on the CanRecoChildren
denominator from LoKi (top) to ThOr (bottom):
Line: Hlt2SingleHighPtMuonIsoDecision Efficiency: 0.970 +/- 0.015
Line: Hlt2SingleHighPtMuonIsoDecision Efficiency: 0.978 +/- 0.013
Rates now (measured on 50k HLT1-filtered min bias):
Line: Hlt2SingleHighPtMuonIsoDecision Incl: 0.13999 +/- 0.0529 kHz, Excl: 0.12000 +/- 0.0489 kHz
Line: Hlt2SingleHighPtMuonDecision Incl: 0.04 +/- 0.0282 kHz, Excl: 0.02 +/- 0.0199 kHz
Line: Hlt2SingleHighPtMuonNoMuIDDecision Incl: 0.24000 +/- 0.0692 kHz, Excl: 0.24000 +/- 0.0692 kHz
Line: Hlt2SingleHighPtMuonPrescaleDecision Incl: 0.04 +/- 0.0282 kHz, Excl: 0.04 +/- 0.0282 kHz
Previous LoKi-based implementation:
Line: Hlt2SingleHighPtMuonIsoDecision Incl: 0.12 +/- 0.04 kHz, Excl: 0.08 +/- 0.03 kHz
Line: Hlt2SingleHighPtMuonDecision Incl: 0.04 +/- 0.02 kHz, Excl: 0.0 +/- 0.0 kHz
Line: Hlt2SingleHighPtMuonNoMuIDDecision Incl: 0.36 +/- 0.08 kHz, Excl: 0.22 +/- 0.06 kHz
Line: Hlt2SingleHighPtMuonPrescaleDecision Incl: 0.02 +/- 0.01 kHz, Excl: 0.0 +/- 0.0 kHz
So compatible within uncertainties.
Edited by Ross John Hunter