Update inclusive radiative lines
Description
Update radincl to
- get rid of the too many combinations problem
- Update preselection
- IsNotH and IsPhoton PID requirements to the photon
- tighter/new filters on V0s in mass window, PT, IPchi2, vtx_chi2
- tighter hh and hhh combination in vtx_vhi2 and DOCA
- use updated BDTs
- without the CorrMass problem
- using all samples available for training
- Go back to target rates, that dropped in the previous MR due to change in the converted photons builder
Rates in local
Using HltEffChecker over 100k Minbias_filtered_v2
Hlt2RD_BToHHGamma_GammaToEEDD_Incl_FullDecision Incl: 0.0 +/- 0.0 kHz, Excl: 0.0 +/- 0.0 kHz
Hlt2RD_BToHHGamma_GammaToEELL_Incl_FullDecision Incl: 0.80999 +/- 0.0899 kHz, Excl: 0.4 +/- 0.0632 kHz
Hlt2RD_BToHHGamma_Incl_FullDecision Incl: 1.01 +/- 0.1004 kHz, Excl: 0.76 +/- 0.0871 kHz
Hlt2RD_BToHHHGamma_GammaToEEDD_Incl_FullDecision Incl: 0.0 +/- 0.0 kHz, Excl: 0.0 +/- 0.0 kHz
Hlt2RD_BToHHHGamma_GammaToEELL_Incl_FullDecision Incl: 0.79 +/- 0.0888 kHz, Excl: 0.33 +/- 0.0574 kHz
Hlt2RD_BToHHHGamma_Incl_FullDecision Incl: 1.0 +/- 0.0999 kHz, Excl: 0.71 +/- 0.0842 kHz
Hlt2 Total Rate: 2.89 +/- 0.2 kHz
Rates and BW from PR test
Propagation to sprucing
Very little impact, mainly to converted photons sprucing lines as expected
Edited by Aniol Lobo Salvia