Draft: Improvement of Lc and Xic MVA lines
Description
This MR is meant to:
- Add second MVA builder for xic0
- Improve variables for Lc0 MVA
- Remove MVA lines from cbaryon_spectroscopy.py
- Add MVA lines to new module cbaryon_spectroscopy_mva.py
- Add dedicated 4-track BDT.
Rates
--------------------------------------------------------------------------------------------------------------
INFO: Starting /afs/cern.ch/work/a/acampove/stack/DaVinci/HltEfficiencyChecker/scripts/hlt_calculate_rates.py...
--------------------------------------------------------------------------------------------------------------
INFO: No lines specified. Defaulting to all...
HLT rates:
--------------------------------------------------------------------------------------------------------------
Line: Hlt2Charm_LcpToPpKmPip_MVA_PRDecision Incl: 0.77777 +/- 0.0718 kHz, Excl: 0.67805 +/- 0.0671 kHz
Line: Hlt2Charm_Xic0ToPpKmKmPip_MVA_PRDecision Incl: 0.36561 +/- 0.0492 kHz, Excl: 0.30579 +/- 0.0450 kHz
Line: Hlt2Charm_XicpToPpKmPip_MVA_PRDecision Incl: 0.31243 +/- 0.0455 kHz, Excl: 0.24596 +/- 0.0404 kHz
--------------------------------------------------------------------------------------------------------------
Hlt2 Total: Rate: 1 +/- 0.1 kHz
--------------------------------------------------------------------------------------------------------------
To be tested with lhcb-datapkg/ParamFiles!91
Edited by Lorenzo Pica