Adding custom BDTs and updating working points
Purpose
This MR will:
- Loosen the preselection.
- Add custom BDTs for each of the four processes trained with run 3 simulation.
- Adjust working points and prescales to satisfy rate requirements.
The rates are:
--------------------------------------------------------------------------------------------------------------
INFO: Starting /afs/cern.ch/work/a/acampove/stack/DaVinci/HltEfficiencyChecker/scripts/hlt_calculate_rates.py...
--------------------------------------------------------------------------------------------------------------
INFO: No lines specified. Defaulting to all...
HLT rates:
--------------------------------------------------------------------------------------------------------------
Line: Hlt2RD_B0ToKpPimEE_MVADecision Incl: 0.03988 +/- 0.0162 kHz, Excl: 0.01994 +/- 0.0115 kHz
Line: Hlt2RD_B0ToKpPimEE_MVA_calDecision Incl: 0.02659 +/- 0.0132 kHz, Excl: 0.01994 +/- 0.0115 kHz
Line: Hlt2RD_B0ToKpPimEE_MVA_misidDecision Incl: 0.01994 +/- 0.0115 kHz, Excl: 0.01329 +/- 0.0094 kHz
Line: Hlt2RD_B0ToKpPimEE_SameSign_MVADecision Incl: 0.03323 +/- 0.0148 kHz, Excl: 0.01329 +/- 0.0094 kHz
Line: Hlt2RD_B0ToKpPimMuMu_MVADecision Incl: 0.01994 +/- 0.0115 kHz, Excl: 0.01329 +/- 0.0094 kHz
Line: Hlt2RD_B0ToKpPimMuMu_SameSign_MVADecision Incl: 0.00664 +/- 0.0066 kHz, Excl: 0.0 +/- 0.0 kHz
Line: Hlt2RD_BsToPhiEE_MVADecision Incl: 0.03323 +/- 0.0148 kHz, Excl: 0.02659 +/- 0.0132 kHz
Line: Hlt2RD_BsToPhiEE_MVA_misidDecision Incl: 0.03323 +/- 0.0148 kHz, Excl: 0.01994 +/- 0.0115 kHz
Line: Hlt2RD_BsToPhiEE_SameSign_MVADecision Incl: 0.00664 +/- 0.0066 kHz, Excl: 0.00664 +/- 0.0066 kHz
Line: Hlt2RD_BsToPhiMuMu_MVADecision Incl: 0.00664 +/- 0.0066 kHz, Excl: 0.0 +/- 0.0 kHz
Line: Hlt2RD_BsToPhiMuMu_SameSign_MVADecision Incl: 0.0 +/- 0.0 kHz, Excl: 0.0 +/- 0.0 kHz
Line: Hlt2RD_BuToKpEE_MVADecision Incl: 0.01329 +/- 0.0094 kHz, Excl: 0.0 +/- 0.0 kHz
Line: Hlt2RD_BuToKpEE_MVA_calDecision Incl: 0.01329 +/- 0.0094 kHz, Excl: 0.00664 +/- 0.0066 kHz
Line: Hlt2RD_BuToKpEE_MVA_misidDecision Incl: 0.01329 +/- 0.0094 kHz, Excl: 0.01329 +/- 0.0094 kHz
Line: Hlt2RD_BuToKpEE_SameSign_MVADecision Incl: 0.01994 +/- 0.0115 kHz, Excl: 0.00664 +/- 0.0066 kHz
Line: Hlt2RD_BuToKpMuMu_MVADecision Incl: 0.01329 +/- 0.0094 kHz, Excl: 0.01329 +/- 0.0094 kHz
Line: Hlt2RD_BuToKpMuMu_SameSign_MVADecision Incl: 0.00664 +/- 0.0066 kHz, Excl: 0.0 +/- 0.0 kHz
Line: Hlt2RD_LbTopKEE_MVADecision Incl: 0.03323 +/- 0.0148 kHz, Excl: 0.03323 +/- 0.0148 kHz
Line: Hlt2RD_LbTopKEE_MVA_misidDecision Incl: 0.01994 +/- 0.0115 kHz, Excl: 0.01994 +/- 0.0115 kHz
Line: Hlt2RD_LbTopKEE_SameSign_MVADecision Incl: 0.0 +/- 0.0 kHz, Excl: 0.0 +/- 0.0 kHz
Line: Hlt2RD_LbTopKMuMu_MVADecision Incl: 0.00664 +/- 0.0066 kHz, Excl: 0.00664 +/- 0.0066 kHz
Line: Hlt2RD_LbTopKMuMu_SameSign_MVADecision Incl: 0.01994 +/- 0.0115 kHz, Excl: 0.01994 +/- 0.0115 kHz
--------------------------------------------------------------------------------------------------------------
Hlt2 Total: Rate: 0 +/- 0.0 kHz
--------------------------------------------------------------------------------------------------------------
Finished printing HLT rates!
The performance plots are:
! | |
---|---|
B^+\to K^+e^+e^- |
B_d\to K^{*0}e^+e^- |
\Lambda_b\to p K^-e^+e^- |
B_s\to \phi(1020)e^+e^- |
Importance
These lines target decays of high interest to LHCb and the current performance is significantly better than the one in the first MR.