Skip to content

BandQ_Buds_HltNoMuonLines_EnlargeJpsiwindow

Chenxu Yu requested to merge yuc/enlarge_jpsiwindow into bandq_development

The new Hlt2line for B2JpsiKp, Bz2JpsiKpPim, Bs2JpsiKpKm for MuonID efficiency study

  • No muon-station based Muon IDs are added
  • Update based on study on early Run3 data
  • enlarge Jpsi-window to +/- 250 MeV

Bandwidth: tested using hlt1 filtered Minibias MC as input.

early 2024 data taking Now After-bandwidth
Bp 3/99998 4/99998 (mTag) 6/99998 (pTag) 350kB/s (mTag), 524kB/s (pTag)
Bs 0/99998 0/171488(mTag) 0/171488(pTag) 0Hz (Bs mTag: require further checking, running 200000 samples)
Bz 4/99998 1/99998 (mTag) 1/99998 (pTag) 84kB/s (mTag), 84kB/s (pTag)

Efficiencies (%)

Before After
Bp 22 ± 1 20 ± 0.3 (mTag) 21 ± 0.4 (pTag)
Bs 7.8 ± 0.18 7.1 ± 0.29 (mTag) 6.7 ± 0.16 (pTag)
Bz 6.6 ± 0.25 6.0 ± 0.25 (mTag) 6.4 ± 0.16 (pTag)

Merge request reports

Loading