Sexaquark lines 2025
This MR improves and tightens the cuts of the already present 7 Sexaquark trigger lines and adds 11 lines. The cuts in the new lines are mostly based on the simulations and 2024 data from the already present trigger lines.
Persistency model: Extra particles are selected, after which these particles along with the triggered candidate are stored or not, based on the number of extra particles that were selected.
The changes in the rate and BW are based on the "hlt2_bandwidth_input_2024" sample:
[After prescales:]
With Changes:
Ran over 10,000 events.
Turbo filesize = 2.07 MB. Turbo Events fired = 395
Turbo Rate = 1.29 MHz * 395 / 10,000 = 51.0 kHz
Turbo BW = 1.29 MHz * 2.07 MB / 10,000 = 267 MB/s
Full-stream filesize = 6.64 MB. Full-stream Events fired = 47
Full-stream Rate = 1.29 MHz * 47 / 10,000 = 6.1 kHz
Full-stream BW = 1.29 MHz * 6.64 MB / 10,000 = 857 MB/s
Without Changes:
Ran over 10,000 events.
Turbo filesize = 2.16 MB. Turbo Events fired = 400
Turbo Rate = 1.29 MHz * 400 / 10,000 = 51.6 kHz
Turbo BW = 1.29 MHz * 2.16 MB / 10,000 = 279 MB/s
Full-stream filesize = 6.64 MB. Full-stream Events fired = 47
Full-stream Rate = 1.29 MHz * 47 / 10,000 = 6.1 kHz
Full-stream BW = 1.29 MHz * 6.64 MB / 10,000 = 857 MB/s
Conclusion:
Change to QEE's Turbo Rate = -0.6 kHz
Change to QEE's Turbo BW = -12 MB/s
Change to QEE's Full-stream Rate = 0 kHz
Change to QEE's Full-stream BW = 0 MB/s