Update of muon showers line after retraining the BDT with HLT1_filtered data
Retraining of the BDT for the muon detector showers line Hlt2QEE_MDS_BDT_nHits with HLT1 filtered data to solve MC/data differences.
We tried to maintain reasonable bandwidth levels without the current prescale of the Hlt2QEE_MDS_BDT_nHits line (0.01) with two distinct processing lines:
- Full-stream – for background studies (a higher cut on the BDT was imposed).
- Turbo – to ensure signal retention if the full-stream cut is too high.
This merge request is associated with the approval of Update of muon-showers weights, which updates the BDT weights after retraining with HLT1-filtered data.
BANDWIDTH TESTS:
We conducted the QEE bandwidth test using 10.000 HLT1-filtered events for the following branches:
-
qee_upgrade (old muon_showers line with a 0.01 prescale)
- Turbo bandwidth: 191.952 MB - Full-stream bandwidth: 516.516 MB - Rate: 516.0 kHz -
muon_showers (new Turbo and full-stream lines with no prescale):
- Turbo bandwidth: 158.412 MB - Full-stream bandwidth: 523.74 MB - Turbo rate: 258.0 kHz - Full-stream rate: 129.0 kHz
Edited by Alberto Martinez Armas