Skip to content

SLB: Tuning baryonic tau hadronic lines and tighten Ks and Lambda builders

We have tuned the selections based on MC samples. Also, a new line Hlt2SLB_LbToLcTauNu_LcToPPiPi_TauToPiPiPiNu has been added. The change in rates compared to sl-june-ts is attached for all the lines, including the new line changes_junets_newvert.log

Ks and Lambda builders are tightened too.

The affected lines are shown here with rates

lines Before After changes
Hlt2SLB_LbToLcTauNu_LcToPKSDD_TauToMuNuNu 108.438 67.7736 -40.6641
Hlt2SLB_LbToLcTauNu_LcToLambdaPiDD_TauToMuNuNu 81.3283 54.2188 -27.1094
Hlt2SLB_LbToLcTauNu_LcToPKSDD_TauToMuNuNu_MuonDecayInFlight 81.3283 54.2188 -27.1094
Hlt2SLB_LbToLcTauNu_LcToPKPi_TauToPiPiPiNu 54.2188 40.6641 -13.5547
Hlt2SLB_Xib0ToXicplusTauNu_XicplusToPKPi_TauToPiPiPiNu 54.2188 40.6641 -13.5547
Hlt2SLB_LbToLcTauNu_LcToPPiPi_TauToPiPiPiNu - 40.6641 New
Hlt2SLB_LbToLcMuNu_LcToLambdaPiDD 13.5547 27.1094 13.5547
Hlt2SLB_LbToLcMuNu_LcToPKSLL_MuonDecayInFlight 13.5547 27.1094 13.5547
Hlt2SLB_XibminusToXic0TauNu_Xic0ToPKKPi_TauToPiPiPiNu 27.1094 13.5547 -13.5547
Hlt2SLB_LbToLcTauNu_LcToPKSDD_TauToMuNuNu_FakeMuon 54.2188 13.5547 -40.6641
Hlt2SLB_LbToLcTauNu_LcToLambdaPiDD_TauToPiPiPiNu 27.1094 13.5547 -13.5547
Hlt2SLB_LbToLcMuNu_LcToPKSDD_FakeMuon 27.1094 13.5547 -13.5547
Hlt2SLB_LbToLcENu_LcToPKSDD 13.5547 0 -13.5547
Hlt2SLB_LbToLcTauNu_LcToPKSDD_TauToPiPiPiNu 27.1094 0 -27.1094
Hlt2SLB_LbToLcTauNu_LcToLambdaPiLL_TauToMuNuNu 27.1094 0 -27.1094
Hlt2SLB_LbToLcMuNu_LcToLambdaPiLL 13.5547 0 -13.5547
Edited by Debashis Sahoo

Merge request reports

Loading