Change output rate of nobias line to 30 kHz for mu=0.1 data

Change filter code of Hlt2NoBias_NoBias line to Hlt1ODINLumiDecision and set prescale to 1.0 to get 30 kHz of nobias events.

Meant to process runs 323128, 323130 and 323131.

The bandwidth of the NOBIAS stream is around 270 MB/s with this configuration, the total bandwidth 320 MB/s. The numbers are determined by running HLT2 over the HLT1 dumps, using zstd -f to get the compressed file size and normalising by the lumi events. As a reference, I got 8.6 GB/s on a normal pp run (323594) without removing the prescale on the nobias line, which is a few per-cent below what we usually quote.

Note for run 323131 an average mu of 0.7 is given in the run db. This is due to the increase of mu in the last 5 minutes of the run, see the figure below. But given that this is only a few minutes it should be fine in terms of bandwidths.

trackmva rate in 323131

Edited by Sascha Stahl

Merge request reports