Adjust selection of IFT Stripping Line
Tightening the selection requirements of the HeMedian
line to adjust a previously too high retention rate.
These stripping lines depend on new LoKi functors, in the corresponding MR Phys!956 (merged).
Please find the retention rates and (CommonParticles overhead-free) timings of our lines, calculated on 200k events (TestMyWGfromSettings.py
), below.
StrippingReport INFO Event 200000, Good event 200000
| *Decision name*|*Rate,%*|*Accepted*| *Mult*|*ms/evt*|
|_StrippingGlobal_ | 0.3000| 600| | 12.737|
|_StrippingSequenceStreamBhadronCompleteEvent_ | 0.3000| 600| | 12.716|
|!StrippingHeNOverflows_Line | 0.0660| 132| 1.076| 0.168|
|!StrippingHeL2ppppiLine | 0.0700| 140| 1.671| 0.116|
|!StrippingLb2dpX_piLine | 0.0475| 95| 1.337| 0.043|
|!StrippingLb2dpX_pipiLine | 0.0425| 85| 1.906| 0.047|
|!StrippingHeMedian_Line | 0.0635| 127| 1.260| 0.198|
|!StrippingLb2V0pphhLLLine | 0.0280| 56| 2.500| 0.095|
|!StrippingLb2V0pphhLLSSLine | 0.0075| 15| 4.133| 0.085|
In the first version of this MR only the prescaling of the HeMedian
line was changed.
Edited by Hendrik Jage