MagFieldServices: Use run-based IOVs for conditions objects
When running with currents set from job options, use the run number as IOV to make sure it is being re-initialized during stop/start. Also cleanup some printouts and remove finalize() methods that only print an INFO message. Relates to ATLASRECTS-5604.
Showing
- MagneticField/MagFieldServices/MagFieldServices/AtlasFieldCacheCondAlg.h 2 additions, 3 deletions...agFieldServices/MagFieldServices/AtlasFieldCacheCondAlg.h
- MagneticField/MagFieldServices/MagFieldServices/AtlasFieldMapCondAlg.h 1 addition, 2 deletions.../MagFieldServices/MagFieldServices/AtlasFieldMapCondAlg.h
- MagneticField/MagFieldServices/src/AtlasFieldCacheCondAlg.cxx 15 additions, 18 deletions...eticField/MagFieldServices/src/AtlasFieldCacheCondAlg.cxx
- MagneticField/MagFieldServices/src/AtlasFieldMapCondAlg.cxx 14 additions, 21 deletionsMagneticField/MagFieldServices/src/AtlasFieldMapCondAlg.cxx