Tags give the ability to mark specific points in history as being important
-
LEDET_v2_02_27
629b442a · ·LEDET_v2_02_27 Main changes: - Added feature: prevent fast/unphysical quench recovery due to sudden disappearing of IFCC/ISCC. The option can be enabled with the non-documented variable "time_window_disabled_quench_recovery", which by default is set to 1 ms.
-
LEDET_v2_02_26
751add31 · ·LEDET_v2_02_26 Main changes: - added plot of QH definition to the 2D simulation report
-
LEDET_v2_02_25
6456be43 · ·LEDET_v2_02_25 Main changes: - Bug fixed: When the newly-introduced option to calculate the hot-spot temperature importing the magnetic field from the simulation is enabled, the half-turn in each coil section (or group) where the highest average magnetic field is reached during the simulation is automatically selected.
-
LEDET_v2_02_24
db939e1b · ·LEDET_v2_02_24 Main changes: - improved speed of txt output writing by 10-100 times
-
LEDET_v2_02_23
029729a8 · ·LEDET_v2_02_23 Main changes: - Improved functionality: allow running a model where some conductors have multiple strands and some are single wires, while enabling the options to include ISCL and strand twist-pitch effect (in this case, these effects will be ignored for single wire conductors).
-
LEDET_v2_02_22
8304a8d1 · ·LEDET_v2_02_22 Main changes: - Added option to import from the simulation the magnetic field to use in the hot-spot temperature calculation. This can be important when the currents in the coil sections are different from each other.
-
LEDET_v2_02_21
7d699fcb · ·LEDET_v2_02_21 Main changes: - Bug fixed: previously Nb-Ti current-sharing temperature resulted in NaN if magnetic field or current density were higher than their critical values - Bug fixed: names of variable to save U_inductive_dynamic_CoilSections were not written to output txt file if the simulation was run via yaml file - Added variable "fractionQuenchedConductor" to the list of variables saved when flag_saveMatFile=2 after a 2D simulation
-
LEDET_v2_02_20
0df6551e · ·LEDET_v2_02_20 Main changes: - important bug fix that affected simulations with silver-matrix conductors such as Bi-2212: 1) silver resistivity used in the quench calculation was wrong, and more than 10 times too high at low temperature. 2) silver resistivity used in the hot-spot temperature calculation during post-processing was wrong: different from the one used in the quench calculation (one or two orders of magnitude lower resistivity), no dependance on magnetic field and RRR. 3) all relevant submodules were updated accordingly.
-
LEDET_v2.02.19
f246d31e · ·LEDET_v2.02.19 Main changes: - Bug fixed: initial current is now correctly set in 3D simulations also in the case of initial current ramping up - Added option: BtX_background and BtY_background are now applied also when 3D simulations are selected (but not if the magnetic field is set at each time step from input files)
-
LEDET_v2.02.18
c09aa71a · ·LEDET_v2.02.18 Main changes: - Bug fixed: Covered the case where the map2d peak field is zero (which previously resulted in an error) - Bug fixed: In pdf report after a 2D simulation: removed indices of the half-turns that were not quenched from the plot "Main cause of quench" - Added fraction of quenched coil to the output .mat file after a 3D sim. Variable name:
-
LEDET_v2.02.17
b0a018ee · ·LEDET_v2.02.17: More stable when running many simulations in a row
-
LEDET_v2.02.16
0d300ccc · ·LEDET_v2.02.16: A few new features and bug fixes
-
LEDET_v2.02.15
353a42ed · ·LEDET_v2.02.15: **BETA, POSSIBLY UNSTABLE** Integrated magnetic-field map calculation
-
LEDET_v2.02.14
fa44cba3 · ·LEDET_v2.02.14. Improved functionalities and bug fixes
-
LEDET_v2.02.13
d8b04e6a · ·LEDET_v2.02.13. Added option to set cooperative-simulation variables in 3D simulations
-
LEDET_v2.02.12
5ae11d25 · ·LEDET_v2.02.12. Added option to disable lead ends conductive cooling in 3D simulations
-
LEDET_v2.02.11
d1eb3b6a · ·Version 2.02.11. Output variables can now be assigned to nodes provided with a mesh of elements.
-
LEDET_v2.02.10
f57b92b7 · ·Version 2.02.10. Added option to perform proximity check on the nodes to be thermally connected (sim3D_flag_checkNodeProximity=1, sim3D_nodeProximityThreshold)
-
LEDET_v2.02.09
614e1cd2 · ·Version 2.02.09. Added option to build busbar geometry (flag_typeWindings=101)