Skip to content

Draft: Multimodule QC-tools

This MR will implement the option to run QC-tools in parallel over several modules. The general idea is that the user will supply multiple connectivity files, like -m1 20UPGR92101012/20UPGR92101012_L2_warm.json -m2 20UPGR92101012/20UPGR92101012_L2_warm.json, and for each module there will be a corresponding power_supply, high_voltage, multimeter, and ntc block in the hardware config file. Outputs will be stored in the same way the are now. More description here: https://cernbox.cern.ch/s/8Rb1lAVI4mwXWK4

This MR builds off of developments in calibADC3 (where option to use calibrated ADC was added). I will rebase to main once !123 (merged) is merged.

Requires this MR in YARR: YARR/YARR!701 (merged)

closes: #70 (closed) #49 (closed)

Edited by Lingxin Meng

Merge request reports

Loading