Use GBT and elink numbers in GBT configuration
Description
Created to match with cmsgemos MR 241. The new output configuration file uses the format PHASE_GBT<n>_ELINK<m> <phase>
for each GBT and each elink.
Related Issue
How Has This Been Tested?
Tested in GE2/1 integration stand at B904. Tested again after newest changes, still working.
Types of changes
-
Bug fix (non-breaking change which fixes an issue) -
New feature (non-breaking change which adds functionality) -
Breaking change (fix or feature that would cause existing functionality to change)
Checklist:
-
My code follows the code style of this project. -
My change requires a change to the documentation. -
I have updated the documentation accordingly. -
I have read the CONTRIBUTING document. -
I have added tests to cover my changes. -
All new and existing tests passed.
Edited by Antonello Pellecchia