Implement the SCA GBT phase scan
Description
This MR adds a phase scan for the SCA e-link. For each phase from 0 to 15 the SCA is reset a number of times (default 100) and the ready state is checked.
It is a bit ugly that we have to read the config-file to apply the phases, but otherwise we overwrite other values and the scan misbehaves. This can be modified once we have the possibility to read back GBT registers.
The raw results are saved in /tmp/gemdata/scaPhaseScan/
. The phases and the corresponding number of failures are printed.
Related Issue
This MR addresses issue #193. We could consider merging the solution with #192 and make it a single scan.
How Has This Been Tested?
Tested on the GE2/1 integration setup in B904.
Types of changes
-
Bug fix (non-breaking change which fixes an issue) -
New feature (non-breaking change which adds functionality) -
Breaking change (fix or feature that would cause existing functionality to change)
Checklist:
-
My code follows the code style of this project. -
My change requires a change to the documentation. -
I have updated the documentation accordingly. -
I have read the CONTRIBUTING document. -
I have added tests to cover my changes. -
All new and existing tests passed.
Edited by Laurent Petre