SCTDataMonitor: Improved monitoring of hit timing
Improving SCT hit time monitoring:
- Updated method of calculating hit time average so that more weight is given to latest value - better for timeseries monitoring?
- Implementing monitoring ratio metric 010 hit count/011 hit count.