Skip to content

Small shift to the SMOG2 cell position

Based on the measurements performed by the CERN alignment team in 2022, the position of the SMOG2 cell was set as [-541, -341] mm. Following analyses of the tomography data and the re-alignment performed after the re-installation in December 2023, a small shift was found, as shown below (full alignment report at this link).

image

This series of MRs applies a small shift to the SMOG2 cell limits in the codebase and goes with Moore!4669 (merged) and Gauss!1145 (merged).

The effect is tested on 24/05/24 MEPs with pp+pAr. No changes is found for pp, while reconstructed PVs in the SMOG2 region increase by a factor 0.5%. The consequent increase in trigger rate is O(1 kHz)

image

cc @pdinezza @chlucare @thboettc @oboenteg

Goes with Moore!4669 (merged) and Gauss!1145 (merged).

Edited by Saverio Mariani

Merge request reports

Loading