Skip to content

Adding CALO raw banks to electron lines

Description

This MR is meant to add CALO raw banks to the MVA turbo lines from the btoxll topology, which have electrons in the final state.

Bandwidths

The tests processed 568K events, the input rate is 1.29 MHz, therefore a scale factor of 2.2 is expected on top of the compressed size. The tests were ran over all the lines in the RD group. The file sizes are:

Subdetector Compressed size [MB] BW [MB] Increase [MB]
No raw banks 208.38 458.43 0
Calo 209.10 460 1.6
Calo and rich 210.0 462 3.6
Calo and FT 210.2 462.4 4.0
Calo and UT 210.0 462 3.6
Calo and VP 210.2 462.4 4.0
All 213.1 469 11

Rates

The rates are all unchanged, the list can be seen here.

Throughput

The numbers seem mostly unchanged between different configurations, with a 1% fluctuation at most:

march_25  HLTControlFlowMgr  Loop over 568655 Events Finished -  WSS 10797.9, timed 468597 Events: 1250919 ms, Evts/s = 374.602
calo      HLTControlFlowMgr  Loop over 568655 Events Finished -  WSS 11213.4, timed 468596 Events: 1239657 ms, Evts/s = 378.005
calo_rich HLTControlFlowMgr  Loop over 568655 Events Finished -  WSS 11552.6, timed 468597 Events: 1237013 ms, Evts/s = 378.813
calo_ft   HLTControlFlowMgr  Loop over 568655 Events Finished -  WSS 11463.7, timed 468598 Events: 1251044 ms, Evts/s = 374.566
calo_ut   HLTControlFlowMgr  Loop over 568655 Events Finished -  WSS 11020.8, timed 468597 Events: 1243631 ms, Evts/s = 376.797
calo_vp   HLTControlFlowMgr  Loop over 568655 Events Finished -  WSS 10576.4, timed 468595 Events: 1243366 ms, Evts/s = 376.876
all_dets  HLTControlFlowMgr  Loop over 568655 Events Finished -  WSS 11315.2, timed 468596 Events: 1237923 ms, Evts/s = 378.534

Merge request reports